:::: E HONG INSTRUMENTS CO., LTD. ::::

回首頁

Index > Products > Analytical Instrument Series > Spectrophotometer
 
Z-2000 Series Polarized Zeeman Atomic Absorption Spectrophotometer
Z-2000 Series Polarized Zeeman Atomic Absorption Spectrophotometer

Easier Operation, More Reliable Analyses and Higher Sensitivity


This is the concept of Z-series polarized Zeeman AAS.Three models are available to meet your specific needs.

High Quality---Excellent Sensitivity using Zeeman Method and Dual Detector.
Compact---Installation Space is Reduced (Z-2300/2700 )
Useful Design---Slim design with built-in Graphite Furnace Autosampler
 
Features

Excellent sensitivity
New optics and improved graphite furnace power supply circuit enhance sensitivity. Using common hollow cathode lamps, Z-2000 Series spectrophotometer is capable of analyzing As, Se and Sb in tap water and environmental water, which previously have only been measurable by using EDL (high-intensity) lamps in conventional graphite furnace analyses.

Model Z-2000
TANDEM TYPE ATOMIC ABSORPTION SPECTROPHOTOMETER
  • The polarized Zeeman method featuring low noise and high stability is adopted for both flame and graphite furnace methods.
  • Highly accurate analysis is achievable with no need for moving sample compartment or adjusting optics.
Model Z-2300
FLAME ATOMIC ABSORPTION SPECTROPHOTOMETER
  • The polarized Zeeman method featuring low noise, high stability and high throughput is adopted for the flame method.
  • The polarized Zeeman method featuring low noise, high stability and high throughput is adopted for the flame method.
Model Z-2700
GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROPHOTOMETER
  • Highly accurate background correction is possible by Direct Current (DC) polarized Zeeman method.
  • Integrated design with autosampler and dustproof cover.


Specifications

Model

Z-2000

Z-2300

Z-2700

Analytical method

Flame/Graphite furnace

Flame

Graphite furnace

Measurement mode Atomic absorption and flame phtometryAtomic absorption spectrometry
OpticsDouble-beam method (Polarized Zeeman method)
Background correction

Polarized Zeeman method

Monochromator

Mount/diffraction grating

Czerny-Turner mount, 1800 Lines/mm, Blazed at 200 nm

Wavelength range, setting

190 to 900 nm, Automatic spectral peak setting

Focal length, reciprocal dispersion

400 mm, 1.3 nm/mm

Slit width4 steps ( 0.2, 0.4, 1.3, 2.6 nm)
DetectorPhotomultiplier 2pieces

Light source

Number of lamps

8 Lamps (turret), 2 Lamps simultaneous lighting

Lamp position control

Automatic position setting, fine adjustment function

Flame part

Zeeman-effect magnet

0.9 Tesla permanent magnet

-

Burner

Pre-mixed fish-tail type

-

Ignition methodPilot flame automatic ignition-
Combustion condition settingAutomatic flow rate setting of combustion gas-

Safety monitoring function

Optical flame monitoring, flame sensor error detection, fuel/auxiliary gas pressure monitoring, drain liquid level monitoring, cooling water flow monitoring, flash-back shock absorption, safety flame extinguishing at power failure (buffer tank method), N2O select safety mechanism, etc.

-

Graphite furnace part

Zeeman-effect magnet

1.0 Tesla permanent magnet

-

1.0 Tesla permanent magnet

Temperature control

50 to 2,800°C, over current protection

50 to 2,800°C, over current protection

Heating current control

Optical temperature control, constant current control

Optical temperature control, constant current control

Gas flow rate controlSheath gas: Ar gas, 3 L/min. Carrier gas: Ar gas 0, 10, 30, 200 mL/min.(4 steps)Sheath gas: Ar gas, 3 L/min. Carrier gas: Ar gas 0, 10, 30, 200 mL/min.(4 steps)

Safety monitoring control

Ar gas pressure monitoring, cooling water flow monitoring, furnace temperature monitoring

Ar gas pressure monitoring, cooling water flow monitoring, furnace temperature monitoring

Graphite furnace autosampler

Number of sample containers

60 pcs (1.5 mL container), 96-well micro plate [option]

-

60 pcs (1.5 mL container), 96-well micro plate [option]

Modifier container

5 pcs(25 mL container)

5 pcs(25 mL container)

Sample injection volume

1 to 100 μL

1 to 100 μL

Sample injection reproducibility

RSD 1% or less (5 to 100μL)

RSD 1% or less (5 to 100μL)

Sample injection speed

Selectable in 5 steps

Selectable in 5 steps

Rinse solution discharge

1 mL

1 mL

Applicable solventsAqueous solution, ethanol, methanol, acetone, MIBKAqueous solution, ethanol, methanol, acetone, MIBK
Carry-over10-5 or less (for standard aqueous solution sample)10-5 or less (for standard aqueous solution sample)
Heating injection functionYesYes
Number of nozzle washing5 times5 times
Sample condensation (in furnace)1 to 25 times1 to 25 times
Sample dilution (in furnace)1 to 10 times1 to 10 times

Data processing

Signal measurement method

Integration, peak height, peak area, peak width

Signal type

Zeeman AA, sample, reference, emission intensity

Calibration curve

Standard sample: Up to 10 points, Calibration curve preparation: Least-squares method and Newton method, Approximation function: 3 kinds, Sensitivity correction function, standard addition method, simple standard addition method

Data processing

Calculation mode, peak width cut-off height designation, removal/restoration/replacement of measurement result, change of order number of calibration curve, sample blank processing, zero correction of calibration curve, baseline correction, statistical calculation (mean value, standard deviation, relative standard deviation, correlation coefficient), detection limit

Quality Control functionSample check (detection limit, reproducibility), STD check, Quality Control sample check, calibration curve check, recovery check
Parameter/data savingMeasurement result and measurement signal, reference signal, instrument status/error information, etc.

Dimensions (mm)/ weight

1,100(W)x~ 630(D)x~ 700(H)/189 kg

750(W)x~ 630(D)x~ 700(H)/106 kg

750(W)x~ 630(D)x~ 700(H)/139 kg

Power

220/230/240 V, 6 kVA, 50/60 Hz

115/220/230/240 V, 0.2 kVA, 50/60 Hz

220/230/240 V, 6kVA, 50/60 Hz